FSDT is used for fail-safe digital signal acquisition, evaluation and transmission of data through any media for digital data transfer, using third-party devices as bridge to the desired communication channel.
- 2-out-of-2 hardware (logic) concept
- Power supply redundancy
- Ethernet network communication redundancy
- Outputs monitoring, short circuit detection
- One point network monitoring
- Matrix-like free signal mapping inside FSDT network
- Up to 254 nodes on the network supported
- Galvanic isolation: power supply // inputs // logic //
communication // outputs - Overvoltage and overcurrent protections
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Vestibulum cursus varius arcu, a tincidunt lectus facilisis in. Sed posuere felis nec magna commodo, at dictum urna dignissim. Integer in justo eget nulla feugiat vehicula id nec eros.
Functionality
The main purpose of FSDT devices is to safely transfer a certain amount of single-bit data from one location of railway signalling equipment to another such location, in both directions. 6/12 parallel digital inputs are constantly scanned in a safe manner, multiplexed and transmitted to an adjacent FSDT device and converted into parallel data bits for the adjacent FSDT outputs.
Safety
The device is developed and certified according to standards EN 50126, EN 50128 and EN 50129 for the highest safety integrity level SIL4, as well as EN 50125-3 for environmental conditions and EN 50121-4 for EMC. FSDT12 is assessed and certified by Certifer Italia SrIU. It is designed for use in a closed transmission system according to EN 50159, Category 2.
Maintenance
There is no need for complex maintenance activities. Device maintenance includes a periodical review of the installed equipment. Reviews include a simple and fast check of proper function of FSDT digital inputs and outputs circuits through corresponding LED indications.
Connectivity
The FSDT has two redundant Ethernet RJ45 ports for communication. The device can be easily connected to a network through standard network equipment. Direct use of dark fibres in optical cable with Ethernet/Fibre converters, or copper twisted pair cables with Ethernet/DSL converters, or existing railway telecommunication network (SDH or similar). All mechanisms of protection, information integrity, information security and fail safe operation are implemented within FSDT itself and do not depend on used communication bridge device, transmission media or communication channel.